Electrical Interfaces

DMD2401/DMD2401L/DMD2401 IBS/IDR Satellite Modem

5-4

TM065 – Rev. 3.3

5.3.7 REMOTE (J7)


The Remote Port (J7) is the RS-485 connection for remote monitor and control of the modem. It
is a 9-Pin Female “D” Connector. Refer to Table 5-5 below for the connector pinouts.

Table 5-5. RS-485 Remote Port – 9-Pin Female “D” Connector (J7)

Pin Number

Signal

Description

Direction

1

RS-485 TxD-B

Transmit Data B

Output

5

GND

Ground

6

RS-485 TxD-A

Transmit Data A

Output

8

RS-485 RxD-B

Receive Data B

Input

9

RS-485 RxD-A

Receive Data A

Input


5.2.9 DATA INTERFACE (J9)


The Data Interface Port (J9) is used for Synchronous Data Interface and allows the use of
RS-422, RS-232, and V.35 Interfaces. It is a 37-Pin Female Connector. Refer to Table 5-6 for
RS-422 connector pinouts, and Tables 5-7 and 5-8 for RS-232 and V.35 adapters.

Table 5-6. Sync Data - 37-Pin Female Connector (J9)

Pin Number

Signal

Description

Direction

4

SD-A

Send Data A (-)

Input

22

SD-B

Send Data B (+)

Input

5

ST-A

Send Timing A (-)

Output

23

ST-B

Send Timing B (+)

Output

6

RD-A

Receive Data A (-)

Output

24

RD-B

Receive Data B (+)

Output

7

RS-A

Request to Send A (-)

Input

25

RS-B

Request to Send B (+)

Input

8

RT-A

Receive Timing A (-)

Output

26

RT-B

Receive Timing B (+)

Output

9

CS-A

Clear to Send A (-)

Output

14

MF

Mod Fault - Open Collector

Output

33

DF

Demod Fault - Open Collector

Output

27

CS-B

Clear to Send B (+)

Output

11*

DM-A

Data Mode A (-)

Output

29*

DM-B

Data Mode B (+)

Output

13

RR-A

Receiver Ready A (-)

Output

31

RR-B

Receiver Ready B (+)

Output