3.2 Monitor

The “MONITOR” level is accessible from the ‘sELECT” menu. The following modem
parameters are displayed in real time when selected.

Raw_BER

Raw bit error rate.
* Range: <1.0E-4 to 2550E-4

Corr_BER

Corrected bit error rate.
* Range: <1.0E-8 to>1E-3

Eb/N0

Energy(bit)/noise ratio.
* Range: <3.2dB to>9.7dB

RxSignal

Receive signal level.
* Range: <-60dBm to>-30dBm

* When the decoder loses lock no data is available and is so indicated.

3.3 Faults

Faults are grouped into the categories of modulator faults, demodulator faults, and
common equipment faults. The “FAULTS” level is accessible from the ‘sELECT” menu.
The following lists outline the faults monitored and displayed in each group.

Mod_Flts - Modulator Faults

RF_Syn

Modulator RF synthesizer fault.

Data_Clk

Transmit data clock activity fault.

TClk_Syn

Transmit clock synthesizer fault.

I-Channl

I channel activity fault.

Q-Channl

Q channel activity fault.

AGC_level

Automatic gain control level fault.

Module

Modulator module fault. Typically indicates that the
modulator module is missing or will not program.

Dmd_Flts - Demodulator/Decoder Faults

C_Detect

Carrier detect fault. Indicates that the decoder is not locked.

RF_Syn

Demodulator RF synthesizer fault.

Data_Clk

Receive data clock activity fault.

I-Channl

I channel activity fault.

Q-Channl

Q channel activity fault.

Dscrambl

Descrambler activity fault.

BER Thrshld

BER Threshold fault. Indicates that the corrected BER
Threshold that is set in the “Utility” menu has been
exceeded.

Module

Demodulator/decoder module fault. Typically indicates that
the demod/decoder module is missing or will not program.

CEQ_Flts - Common Equipment Faults

Battery

Battery fault.

-12 volt

Negative 12 volt power supply fault.

+12 volt

Plus 12 volt power supply fault.

+5 volt

Plus 5 volt power supply fault.

Controlr

Controller fault. Typically indicates that the controller has
gone through a power on-off cycle.

Intrface

Interface module fault. Typically indicates that the interface
module is missing or will not program.