SDM-309B Satellite Modem
Remote Control
MN/U-SDM309B Rev. #
B-B–25
INS_xxx”cr”
Insert (OK/FLT)
BWA_xxx”cr”
Receive Backward Alarm (OK/FLT)
BER_xxx”cr”
Frame BER (OK/FLT)
RXD_xxx”cr”
Receive Data Loss/AIS (OK/FLT)
OVFL_xxx”cr”
Buffer Overflow (OK/FLT)
UNFL_xxx”cr””lf”]
Buffer Underflow (OK/FLT)
5.17 Bulk Consolidated Status
This command causes bulk modem status to be returned. To reduce the length of the
response, message parameter data are returned without identifiers. However, parameter
identification can be determined by order of return. Each status parameter is terminated
with a “,” (comma) except for the last parameter which has the standard message
termination sequence (“cr””lf”]). The maximum number of characters returned is
approxamately 230. Most of the data returned is formated the same way as the single
command status request (refer to the appropriate portions of this document in preceeding
Sections).
Command:
Response: >add/BCS_p1,p2,p3, . . . pn”cr””lf”] Where “pn” is the last parameter returned. Parameter 1 (p1): Modulator RF output ON/OFF. p1 = n, where “n” is “0” to indicate off or “1” to indicate on. Parameter 2 (p2): Modulator IF frequency. p2 = nnn.nnnn, where “nnn.nnnn” is the modulator IF frequency in MHz. Parameter 3 (p3): Modulator output power level. p3 = snn.n, where ‘snn.n” transmitter power output power level in dBm. Parameter 4 (p4): Modulator rate currently programmed. p4 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 5 (p5): Modulator filter A assignment. p5 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 6 (p6): Modulator filter B assignment. p6 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 7 (p7): Modulator filter C assignment. p7 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 8 (p8): Modulator filter D assignment. p8 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 9 (p9): Carrier only mode ON/OFF. p9 = n, where “n” is “0” to indicate off or “1” to indicate on. Parameter 10 (p10): Differential encoder enable ON/OFF. p10 = n, where “n” is “0” to indicate off or “1” to indicate on. Parameter 11 (p11): Demodulator IF frequency. p11 = nnn.nnnn, where “nnn.nnnn” is the demodulator IF frequency in MHz. Parameter 12 (p12): Demodulator rate currently programmed. p12 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 13 (p13): Demodulator filter A assignment. p13 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 14 (p14): Demodulator filter B assignment. p14 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 15 (p15): Demodulator filter C assignment. p15 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps. Parameter 16 (p16): Demodulator filter D assignment. p16 = nnn_mmmm.m, where “nnn” is the code rate and “mmmm.m” is the data rate in Kbps.