Remote Control
SDM-309B Satellite Modem
B-B–6
MN/U-SDM309B Rev. #
Status Only:
Response: >add/DF_nn.nnnn”cr””lf”] 4.2.2 Demodulator Rate The demodulator has four symbol rate filters. Each filter is for a specific symbol rate. *VARIABLE RATE DEMODULATOR OPTION* 4.2.2.1 Demodulator Filter Rate Assignment Command: (x = A,B,C, or D Filter designator) Response: >add/ADRx_nnn_mmmm.m”cr””lf”] Status Only: Response: >add/ADRx_nnn_mmmm.m”cr””lf”] Note: The parameters nnn_mmmm.m may be replaced by N/A to indicate no assignment. Example: Command: Response: >add/ADRx_N/A”cr””lf”] 4.2.2.2 Select Demodulator Rate Command: (x = A,B,C, or D Filter designator) Response: >add/SDRx_”cr””lf”] Status Only: see DR command. Note: If the MODEM is commanded to a filter (rate) which is not assigned (N/A) the
The data rate and decoder rate for each filter must be established upon initial
demodulator installation and when circumstances indicate the need to do so. Filters are
designated as A, B, C, and D. If a filter is not physically present in the system it may be
assigned N/A (not assigned). Additionally filters which are factory programmed may not
be remotely programmed and will return the "error 5" message when a programming
command is issued.
Demodulators with the variable rate option installed may have four preprogrammed rates
available by using the filter rate assignment commands. These rates are selected using
the standard ‘sDRx_" commands. Modems that have the variable rate option installed
will also respond to the special ‘sDRV_" command. This allows for truly variable rate
control while maintaining compatibility with previous systems.
(nnn = 1/2,3/4, or 7/8 Decoder rate)
(mmmm.m = 48.0 to 4080.0 Data rate)
error 2 message will be returned.