4.1.3.1 Modulator Filter Rate Assignment
Command:
(x = A,B,C, or D Filter designator) Response: >add/AMRx_nnn_mmmm.m”cr””lf”] Status Only: Response: >add/AMRx_nnn_mmmm.m”cr””lf”] Note: The parameters nnn_mmmm.m may be replaced by N/A to indicate no assignment. Example: Command: Response: > add/AMRx_N/A”cr””lf”] 4.1.3.2 Select Modulator Rate Command: (x = A,B,C, or D Filter designator) Response: >add/SMRx_”cr”RF_OFF”cr””lf”] Setting the modulator turns off the RF transmitter. Status Only: see MR command. Note: If the MODEM is commanded to a filter (rate) which is not assigned (N/A) the 4.1.3.3 Select Modulator Rate Variable *Variable Rate Option Only* Command: (nnn = 1/2,3/4, or 7/8 Coder rate) Response: >add/SMRV_nnn_mmmm.m”cr””lf”] RF_OFF”cr””lf”] *Setting the modulator turns off the RF transmitter. Status Only: see MR command.
(nnn = 1/2,3/4, or 7/8 Coder rate)
(mmmm.m = 48.0 to 4080.0 (Data rate)
error 2 message will be returned.
(mmmm.m = 48.0 to 4080.0 Data rate)