beautypg.com

1 modulator filter rate assignment, 2 select modulator rate – Comtech EF Data SDM-309B User Manual

Page 181

background image

Remote Control

SDM-309B Satellite Modem

B-B–4

MN/U-SDM309B Rev. #

the standard ‘sMRx_" commands. Modems that have the variable rate option installed
will also respond to the special ‘sMRV_" command.

4.1.3.1 Modulator Filter Rate Assignment

Command:

(x = A,B,C, or D Filter designator)
(nnn = 1/2,3/4, or 7/8 Coder rate)
(mmmm.m = 48.0 to 4080.0 (Data rate)

Response:

>add/AMRx_nnn_mmmm.m”cr””lf”]

Status Only:

Response:

>add/AMRx_nnn_mmmm.m”cr””lf”]

Note: The parameters nnn_mmmm.m may be replaced by N/A to indicate no assignment.

Example:

Command:

Response:

>

add/AMRx_N/A”cr””lf”]

4.1.3.2 Select Modulator Rate

Command:

(x = A,B,C, or D Filter designator)

Response:

>add/SMRx_”cr”RF_OFF”cr””lf”]

Setting the modulator turns off the RF transmitter.

Status Only:

see MR command.

Note: If the MODEM is commanded to a filter (rate) which is not assigned (N/A) the
error 2 message will be returned.

4.1.3.3 Select Modulator Rate Variable

*Variable Rate Option Only*

Command:

(nnn = 1/2,3/4, or 7/8 Coder rate)
(mmmm.m = 48.0 to 4080.0 Data rate)

Response:

>add/SMRV_nnn_mmmm.m”cr””lf”] RF_OFF”cr””lf”]

*Setting the modulator turns off the RF transmitter.

Status Only:

see MR command.