4 set modulator power offset, 5 set modulator output power level, 6 differential encoder enable – Comtech EF Data SDM-309B User Manual
Page 182: 2 demodulator configuration commands
SDM-309B Satellite Modem
Remote Control
MN/U-SDM309B Rev. #
B-B–5
4.1.4 Set Modulator Power Offset
Command:
Response: >add/MPO_snn.n”cr””lf”] snn.n = +20.0 to -20.0 in 0.5dB increments. Note: This will be the highet modulator power that will be displayed and programmed. Status Only: Response: >add/MPO_snn.n”cr””lf”] 4.1.5 Set Modulator Output Power Level Command: Response: >add/MOP_snn.n”cr””lf”] snn.n = +20.0 to -45.0 in 0.5dB increments for 140MHz modulator. Note: Must be within 25.0dB of the modulator power offset value (see MPO_) for the Status Only: Response: >add/MOP_snn.n”cr””lf”] 4.1.6 Differential Encoder Enable Command: (xxx = ON or OFF) Response: >add/DENC_xxx”cr”lf”] Status Only: Response: >add/DENC_xxx”cr”lf”] 4.2 Demodulator Configuration Commands 4.2.1 Set Demodulator Frequency (to nnn.nnnn MHZ, nnn.nnnn = 50.0000- Command: Response: >add/DF_nnn.nnnn”cr””lf”] Note: nnn.nnnn = 50.0000 to 90.0000 and 100.0000 to 180.0000 for the 140MHz
Use the MOP_ command to actually change the modulator output power.
snn.n = +20.0 to -30.0 in 0.5dB increments for 70MHz modulator.
140MHz modulator and within 10.0dB of the modulator power offset for the 70MHz
modulator.
90.0000)
demodulator.