4 end character, 0 configuration commands/responses, 1 modulator configuration commands – Comtech EF Data SDM-309B User Manual
Page 180: 2 set rf output on/off, 3 modulator rate
SDM-309B Satellite Modem
Remote Control
MN/U-SDM309B Rev. #
B-B–3
Each message is ended with a single character which signals the end of message. This
characters is:
! “cr”
(carriage return character) for commands.
! “]”
(end bracket) for responses.
4.0 Configuration Commands/Responses
4.1 Modulator Configuration Commands
4.1.1 Set Modulator Frequency (to nnn.nnnn MHZ, nnn.nnnn = 50.0000-
90.0000)
Command:
Response: >add/MF_nnn.nnnn”cr” RF_OFF”cr””lf”] Note: When modulator frequency is changed the RF output is switched off. nnn.nnnn = Status Only: Response: >add/MF_nnn.nnnn”cr””lf”] 4.1.2 Set RF Output ON/OFF Command: (xxx = ON or OFF) Response: >add/RF_xxx”cr””lf”] Status Only: ” Response: >add/RF_xxx”cr””lf”] 4.1.3 Modulator Rate The modulator has four symbol rate filters. Each filter is for a specific symbol rate. The *VARIABLE RATE MODULATOR OPTION*
50.0000 to 90.0000 and 100.0000 to 180.0000 for the 140MHz modulator.
data rate and coder rate for each filter must be established upon initial modulator
installation and when circumstances indicate the need to do so. Filters are designated as
A, B, C, and D. If a filter is not physically present in the system it may be assigned N/A
(not assigned). Additionally filters which are factory programmed may not be remotely
programmed and will return the "error 5" message when a programming command is
issued.
Modulators with the variable rate option installed may have four preprogrammed rates
available by using the filter rate assignment commands. These rates are selected using