Paxar Monarch 9850 User Manual
Page 98

X4. data_type
Data type. Options:
0
ASCII Hex - default (ASCII representation of Hex)
1
ASCII
2
ASCII Binary (ASCII representation of Binary)
3
Hex
Multiple data types are offered, which allows flexibility and
compatibility with your host system. You should know the
data type your host provides. If you are unsure, see the
examples on the following pages.
For example, the letter A has a decimal value of 65 in the
ASCII table. The hex (base 16) equivalent of decimal (base
10) is 41. Hex 41 in binary notation is 01000001.
Data Type
Character
MPCL Batch Data for a 96-bit RFID tag
ASCII Hex
41
"414141414141414141414141"
ASCII
A
"AAAAAAAAAAAA"
ASCII Binary
01000001
"010000010100000101000001010000010100000101000001
010000010100000101000001010000010100000101000001"
Hex
~065
"~065~065~065~065~065~065~065~065~065~065~065~065"
Example
X,5,24,0
p
Defines an RFID Data Field (field #5) with exactly 24 ASCII Hex
characters for a 96-bit RFID tag.
Sample Format
{F,1,A,R,E,600,400,"RDCI"
p
L,V,500,115,90,85,3
p
L,V,298,245,90,102,3
p
C,568,8,0,2,2,2,B,L,0,0,"FROM:",0
p
C,568,125,0,2,2,2,B,L,0,0,"CARRIER:",0
p
C,387,8,0,2,1,1,B,L,0,0,"(420) SHIP TO POSTAL CODE",0
p
C,391,250,0,2,1,1,B,L,0,0,"APPOINTMENT NUMBER:",0
p
C,327,250,0,2,1,1,B,L,0,0,"ITEM:",0
p
C,190,8,0,2,1,1,B,L,0,0,"UPC SHIPPING CONTAINER CODE",0
p
T,1,15,V,529,220,0,2,2,2,B,L,0,0,0
p
B,3,13,V,311,28,8,4,50,8,L,0
p
B,4,14,V,17,60,50,5,130,8,L,0
p
X,5,24,0
p
T,6,20,V,415,270,0,50,15,15,B,L,0,2
p
R,4,5,1,16,1,0
p
.
.
.}
RFID Field
Copy Option from field 5
(RFID Field) to field 6
(Text Field)
3-32 Defining Fields