3.4.3.E.b Output Condition Settings
When Output Type (No. 1, Figure 3-27)
is set to be Normal, Toggle or Pulse, the options
similar to the figure below become available.
Figure 3-29
There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions 
are Door/Gate/Relay conditions and 2 conditions are Input/Reader conditions. Each 
condition is related to each other through AND/OR. AND means that all conditions with AND 
must be triggered before the output is triggered. OR means that only 1 of the condition with 
OR is needed to be triggered before the output is triggered. It is also valid to have certain 
conditions as AND and certain conditions as OR. 
 
For Pulse output type, the output is triggered for the amount of time set in the Sec field 
(seconds). 
 
In the Output Condition settings, these Output Type and Output Condition become 
available: 
Output Condition
Output Type
Door #
Gate #
Relay #
Input/Reader
Access Granted Access Granted Access Granted
Access Denied
Access Denied
Access Denied
Fire Alarm
Fire Alarm
Fire Alarm
Tamper
Tamper
Tamper
Duress Event
Duress Event
Duress Event
Held Open
Held Open
Forced Open
Forced Open
Exit Button
Exit Button
Normal 
Toggle 
Pulse 
 
Door Contact
Car Detection
Select None to 
disable the 
condition, or 
select between 
Input 1 and 
Input 8, 
Wiegand A and 
Wiegand H, or 
Reader 00 to 
Reader 03 to 
trigger the 
output. 
Available in Pulse
2 x Door/Gate/Relay Condition
2 x Input/Reader Condition