2 programming the gv-as110 – AGI Security GV-CONCT User Manual
Page 42

32
2.3.2 Programming the GV-AS110
The command codes used to program various functions on GV-AS110 are listed below. All
command codes will start with an asterisk * to clear all previous commands and end with a
number sign # to send the command. After typing the command code, present the Enroll
Card or the Delete Card.
IMPORTANT: Once connecting to GV-AS110, GV-ASManager will load its parameters to
GV-AS110. That means some of settings you program here may be overwritten by GV-
ASManager later.
Function
Command Code
Description
Set Password
*
779_ _ _ _ _ _ _ _ #
4-8 digits
You can set a password to open the door using
this password. The Authentication Mode must
be set to Fixed Card/Common mode. Refer to
the Set Authentication Mode function below.
For example, to set the door’s password as
12345, press *77912345# on the keypad.
Lock Reset
Time
*
578_ _ _ #
1-255 seconds
Sets a time that the door/gate will remain open
after which the door will automatically be
locked.
For example, to set the lock reset time to be
120 seconds, press *578120#
Held Open
Time
*
468_ _ _ _ #
5-9999 seconds
Sets the time that a door/gate can be held open
before an alarm is generated. If the number of
seconds is less than 4 digits, add zeros in front
of the number to make it 4 digits.
For example, to set the held open time to be
180 seconds, enter *4680180#
Set Fire Action
*
732_#
UnchangedÎ0
Unlock DoorÎ1
Lock DoorÎ2
This function locks or unlocks the door/gate, or
maintains the current status when a fire
emergency occurs.
For example, to unlock door during a fire
emergency, press *7321#
Local Anti-
Passback
*
527_#
0ÎDisable
1ÎEnable
Local Anti-passback prevents card sharing by
not allowing a card to go through an entry twice
before first exiting.
For example, to enable Local Anti-passback,
press *5271#
Set Alarm
*
723_ _ _ _#
For the first blank digit, enter a number from
options 0 to 4. For the second blank digit, type