AGI Security GV-CONCT User Manual
Page 72

62
[Alarm]
Select Yes or No to enable or disable the alarm function. If you have defined the alarm
conditions in the Input Setting page (Figure 3-24), remember to activate the corresponding
alarms here; otherwise, even though the alarm conditions are met, the expected alarm will
not be triggered. The default settings for all the alarms are set to NO.
•
When Door Control is selected in the Function Setting page (Figure 3-20), these
options become available:
Option
Description
Held Open
This alarm activates whenever the door is held open over the set
period of time.
Forced Open
This alarm activates whenever the door is opened by force.
Fire Alarm
This alarm activates whenever fire is detected.
Access Denied
This alarm activates whenever entry is denied due to using the
wrong card or entering the wrong password.
Tamper
This alarm activates whenever vandalism occurs, e.g. the opening
of controller’s cabinet.
•
When Parking Control is selected in the Function Setting page (Figure 3-20), these
options become available:
Option
Description
Held Open
Tamper
Fire Alarm
Access Denied
See the same option above.
•
When Elevator Control is selected in the Function Setting page (Figure 3-20), these
options become available:
Option
Description
Tamper
Fire Alarm
Access Denied
See the same option above.