D*ap4 – Junger Audio D*AP4 FLX / D*AP4 LM Edition User Manual
Page 70
D*AP4
65
Important note ! This is the way to create your own
snap shot
. The new presets will be automatically
given the name of this event! So be careful to select meaningful names. You will find them later on in your
function blocks!
Include these Blocks
[System / Interface / Routing / Audio Processor / Voice 1 / Voice 2 /
Program / Monitor]
You can tell the event manager which function blocks must be included
in this event (or not).
Setup GUI – EVENTS – Events – Parameter Events
Parameter events are designed to change parameters when executing an action. You define the
parameter here:
This example shows the possible parameters to control the loudness measurement of the loudness
logger of the Junger Audio application manager J*AM.
Category
[Audio Processor / Measurement]
Subcategory
[in case of Category = Audio Processor >> On Air Tools]
[in case of Category = Measurement >> Loudness]
Parameter
depending on the pre-selected Subcategory you may define the
relevant parameter which you want to set.
Expression
If applicable, the value of the parameter that will be set if the parameter
event is triggered during an event action.