D*ap4 – Junger Audio D*AP4 FLX / D*AP4 LM Edition User Manual
Page 38
D*AP4
33
Mode
[Switched / Redundant]
Redundant – The interface will duplicate the audio traffic to both
Ethernet ports.
Switched
– The second port behaves like a standard switch port
allowing daisy-chaining through the interface. I.e. IP
configuration is only available for Redundant mode.
Primary Address Setup
Setup of the primary network interface
Network Status
[Offline / Connected + bandwidth]
DHCP – Automatic IP Config. [OFF / ON]
IP-Address
Netmask
DNS Server
Gateway
MAC Address
Secondary Address Setup
Setup of the secondary network interface
Network Status
[Offline / Connected + bandwidth]
DHCP – Automatic IP Config. [OFF / ON]
IP-Address
Netmask
DNS Server
Gateway
MAC Address
[unknown / address]
Setup GUI – INTERFACES – 8 Ch Analog Out Interface
Analog Output Calibration
sets the factor for D/A conversion
(dBu) (level for digital 0 dBFS)
ANLx (dBu)
[0.0 … 15.0 … 24.0]
output level for output "x" at 0 dBFS.
The default setting of 15.0dBu correlates to the 6dBu = -9dBFS
conversion.