D*ap4 – Junger Audio D*AP4 FLX / D*AP4 LM Edition User Manual
Page 51
D*AP4
46
Setup GUI – AUDIO PROCESSOR – Dynamics
Link
[Unlinked, Linked]
For mono operation you may
unlink the setup parameters
(see Program 2 for example).
Expander
[ON / OFF]
Threshold (dB)
[-60.0 … -20.0]
Range (dB)
[0.0 … 10.0 … 20.0 / Gate]
Release Mode
[0 … 4 … 9]
Compressor
[ON / OFF]
Reference
[-40 … -18 … 0]
Level (dBFS)
Range (dB)
[0 … 8 … 20]
Ratio
[1.1 … 2.0 … 4.0]]
Processing
[Live / Speech / Pop / Uni /
Classic]
Expert
[ON / OFF]
Clear Processing
History
pressing the soft button will clear
the processing history of the
dynamics control loops.
The parameters of the dynamic section are explained below in reference to the curves:
Jünger Audio Expander
Threshold Signals below threshold are processed,
signals above pass unaffected. Please be
aware that this is only true in Gate mode,
as the Expander mode features soft knee
characteristics.
Range
Maximum reduction range. Its value
determines the maximum reduction of the
input signal. This parameter is
sometimes called 'floor', but differs in
terminology. A floor level is defined as an
absolute value in dBFS, no matter where
the threshold is set. Range defines the
relative range of reduction in dB below
threshold and is thus independent from
absolute values. When it is set to
'Gate' the input signal is muted.
Release
The release mode controls the timing of
Mode
the closing of the Gate/Expander.
Release mode 0 is very fast and even
short gaps or signal intermissions lead to
gain reduction. On the other end of the
scale, 9 is a very slow mode with a
relaxed handling of gaps and low level
periods. All modes feature the same
super fast opening when the signal
returns above threshold.