D*ap4 – Junger Audio D*AP4 FLX / D*AP4 LM Edition User Manual
Page 59
D*AP4
54
The screenshot above shows an example curve of the calculated MPX power
[MPX Power 60 s] (orange). For convenient analysis and set up the graph allows to display a second
MPX curve [MPX Power User] (green) with a user defined integration time. This is especially useful to
see why the MPX Limiter starts working although the MPX power has not reached threshold.
The purple curve shows the gain reduction action of the MPX Limiter. The center white line represents
the selected MPX Limiter reference.
Program
[Program 1 / Program 2]
Selects which of the two programs will be displayed on the graph
Graph
Enable MPX Power User
[OFF / ON]
Enables the display of the user-defined curve
User Integration Time (s) [1 … 40]
This is only a measurement parameter that has no influence on the
MPX Limiter processing
Time Range (min)
[1 / 2 / 5 / 10 / 20 / 30]
Sets the time scale for the MPX power display. The Current
Measurement displays the numerical values of the MPX power
measurement:
Current Measurement
Reset Max
resets Duration and
MPX Max value
Duration
since reset
MPX Power 60s (dBr)
current MPX power
MPX Max (dBr)
maximum value
since reset
Pre-Emphasis Limiter (%) bar graph to show
the amount of high
frequency filtering
applied
Recent Measurement
Duration
elapsed time since
MPX Max (dBr)
maximum MPX power value detected
In the next section the operator can set the audio relevant parameters of the FM conditioning process:
FM Conditioner
[ON / OFF]
Setup Gain (dB)
[-4.0 … 0.0 … 10.0]
can be used to adapt
loudness processed
signals to MPX criteria
or level matching
Pre-Emphasis
[0.0 … 2.0 … 15.0]
Headroom (dB)
MPX Limiter Profile
[Soft / Mid / Hard]
True Peak Limiter
[0 / 1 Live / 2 Speech /
Profile
3 Pop / 4 Uni / 5 / 6
Classic /
7 / 8 / 9]
Max True Peak (dBTP) [read only]