D*AP4

47

o

u

tp

u

t

input

reference

level

compression ratios

ra

n

g

e

ra

n

g

e

Jünger Audio – Upward Compressor

Reference Not to be confused with threshold, this
Level

parameter defines the turning point of the

(dBFS)

response curve from upward to
downward compression (see picture).
When set to 0 dBFS, the signal is
amplified according to the ratio and range
settings.

Range (dB) This defines the range over which

dynamic compression is applied as
defined by the ratio setting. Signals
outside of this range are still reduced or
amplified but not altered in their dynamic
structure.

Ratio

Determines the amount of gain reduction
by a selectable ratio. Although the same
in mathematical terms, understanding is
easier when differentiating between
upward and downward compression:


Processing

The timing characteristics of the compressor are generated adaptively
according to the incoming signal structure. The overall timing can be
set up from fast and responsive settings (lower numbers) to relaxed
settings (higher numbers) without detailed access to the actual micro
timings. The names behind some of the numbers may help to easily
find adequate values to your content.

Expert

[ON / OFF]

Clear Processing History

This is a triggered action that resets the dynamic processing without
any release time. Imagine it as a short circuit to the timing circuits of
an analog dynamic processor which discharges the whole system and
immediately returns the dynamic gain to its neutral state. This function
is useful to reset the process when switching programs (e.g. from
movie to commercial breaks).