3modbus/tcp - data areas, 4 assignment of data areas – Pilz PNOZ mmc1p ETH User Manual
Page 30
3.4
Assignment of data areas
3
Modbus/TCP - Data areas
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
3-20
Register 938 to 944 "Element enable 1 ... 100"
Each element is assigned an ID in the PNOZmulti Configurator. If the el-
ement's output = 0 (no enable), the corresponding bit is set.
Register 1071 to 1126 "Element type"
The available element types are listed below.
1118
17903... 17888
Element type
Element ID = 90
Element ID = 89
1119
17919... 17904
Element type
0
Element ID = 91
1120
17935... 17920
Element type
Element ID = 93
Element ID = 92
1121
17951... 17936
Element type
Element ID = 95
Element ID = 94
1122
17967... 17952
Element type
Element ID = 97
Element ID = 96
1123
17983... 17968
Element type
Element ID = 99
Element ID = 98
1124
17999... 17984
Element type
Reserved
Element ID = 100
1125
18015... 18000
Element type
Reserved
Reserved
1126
18031... 18016
Element type
Reserved
Reserved
Byte 0
8
7
6
5
4
3
2
1
Byte 1
16
15
14
13
12
11
10
9
Byte 2
24
23
22
21
20
19
18
17
...
Byte 10
88
87
86
85
84
83
82
81
Byte 11
96
95
94
93
92
91
90
89
Byte 12
-
-
-
-
100
99
98
97
Element type
(Byte)
Element
Function elements
01
Switch type 1: N/C contact
02
Switch type 1: N/C contact, monitored reset
03
Switch type 1: N/C contact, manual reset
04
Switch type 1: N/C contact, start-up test
05
Switch type 1: N/C contact, start-up test, monitored reset
06
Switch type 1: N/C contact, start-up test, manual reset
Register
(3x)
Coil/
Discrete Input
(1x)
Content
High Byte
Low Byte