3modbus/tcp - data areas, 4 assignment of data areas – Pilz PNOZ mmc1p ETH User Manual
Page 23
![background image](https://www.manualsdir.com/files/762617/content/doc023.png)
Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany
Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: [email protected]
3-13
3.4
Assignment of data areas
3
Modbus/TCP - Data areas
Register 896 "LEDs" and Register 924 to 926 “LEDs expansion mo-
dule, left"
0x00 = LED off
0xFF = LED on
0x30 = LED flashes
Register 910 to 911 "LEDs fieldbus"
Position of LED1 ... LED4:
907
14527... 14512
LEDs expansion module, right
LED right 5
LED right 4
908
14543... 14528
LEDs expansion module, right
LED right 7
LED right 6
909
14559... 14544
LED right 8 / res
Reserved
LED right 8
910
14575... 14560
LEDs fieldbus status
LED 2
LED 1
911
14591... 14576
LEDs fieldbus status
LED 4
LED 3
912
14607... 14592
0
913
14623... 14608
0
914
14639... 14624
0
915
14655... 14640
0
916
14671... 14656
0
917
14687... 14672
LEDs speed monitor 1
Axis 2
Axis 1
918
14703... 14688
LEDs speed monitor 2
Axis 2
Axis 1
919
14719... 14704
LEDs speed monitor 3
Axis 2
Axis 1
920
14735... 14720
LEDs speed monitor 4
Axis 2
Axis 1
921
14751... 14736
0
922
14767... 14752
0
923
14783... 14768
0
924
14799... 14784
LEDs expansion module, left
Left 2
Left 1
925
14815... 14800
LEDs expansion module, left
Left 4
Left 3
926
14831... 14816
LEDs expansion module, left
Left 6
Left 5
927
14847... 14832
0
928
14863... 14848
0
929
14879... 14864
0
930
14895... 14880
0
Register
(3x)
Discrete Input
(1x)
Content
High Byte
Low Byte
PNOZ mc...
LED2
LED1
LED3
LED4