1 • introduction, Control panel – Pitney Bowes DI425 FastPac Inserting Systems User Manual
Page 14
1 • Introduction
1-8
SV61656 Rev. A
Control Panel
Control Panel Buttons
Default — Press this button to return the machine to its default or
‘standard’ settings. These settings come pre-configured from the
factory but can be modified to suit your needs by a Pitney Bowes
Service Representative.
Job — Press to step through the jobs you’ve programmed into the
machine’s memory. The machine will store up to 20 jobs. See page
2-9 for details of programming jobs.
Reset Counter — Press to reset the item or batch counter.
Clear Deck — Press to jog material through and out of the system.
Use clear deck to clear the machine and make it ready for automatic
operation after a stoppage has occurred.
Trial Piece — Press to run a single test piece so that you can
check machine setup. You MUST run a trial piece before you begin
automatic operation by pressing the
Start button. If you’re using
double detection, the machine sets itself automatically as it runs the
trial piece. This envelope will be unsealed and counted as one item.
Start — Starts automatic operation.
Stop — Stops automatic operation at the end of the next cycle.
Delete — Use in setup mode to delete a programmed job from
memory.
Setup — Press to enter the machine setup mode. This mode allows
you to program jobs into memory for instant recall using the
Job
button.
Change + – In setup mode, press + or - to select options or set
values of machine settings.
Prev. ◄ ► Next — In setup mode, use these keys to step backward
or forward through the various job settings.