beautypg.com

Hanna Instruments HI 8050 User Manual

Page 7

background image

7

The following are setting requirements for each irrigation program:

- the working period (between start date (day/month) and end date

(day/month)) – use panel S29

S29

S29

S29

S29 (ACTIVE TIMETABLE)

- the working time during a day (between start time and end time) – use

panel S29

S29

S29

S29

S29 (ACTIVE TIMETABLE)

- the cycle work / rest day can be set using panel S30

S30

S30

S30

S30 (WORKDAY)

- the working days in a week – use panel S30

S30

S30

S30

S30 (WORKDAY)

Working time status for each irrigation program, if selected (irrigation
program is in work period of month, day and week) is displayed in panel
C07

C07

C07

C07

C07 (WORK TIME COND).
The percent of irrigation time or set volume can be automatically modified
by the following:

- MANU

MANU

MANU

MANU

MANUAL F

AL F

AL F

AL F

AL FA

AA

AACT

CT

CT

CT

CTOR

OR

OR

OR

OR: This option can be set using panel S44

S44

S44

S44

S44 (IRRI-

GATION CORR). Percentage and corresponding value of time or
volume can be viewed using panel C10

C10

C10

C10

C10 (MAN CORRECTION).

- TEMPERA

TEMPERA

TEMPERA

TEMPERA

TEMPERATURE

TURE

TURE

TURE

TURE: This option can be set using panel S44

S44

S44

S44

S44 (IRRIGA-

TION CORR).

Total correction percentage, time or volume value is displayed on panel
C11

C11

C11

C11

C11 (TOTAL CORRECTION).
In each irrigation program the pre-irrigation and post-irrigation time or
volume value (used to clean the irrigation pipes with pre-irrigation water)
can be set using panel S35

S35

S35

S35

S35 (PRE/POST IRRIG).

Panel C01

C01

C01

C01

C01 (GENERAL INFO) displays the active irrigation program and

active sectors.
The active irrigation program is displayed on panel C03

C03

C03

C03

C03 (SENSORS STATE).

Related data regarding the active irrigation program (active irrigation pro-
gram number, last start condition and current / set repetition number) are
displayed on panel C04

C04

C04

C04

C04 (PROGRAM STATE).

Information about selected irrigation program, priority and irrigation pro-
gram conflict are displayed on panel C08

C08

C08

C08

C08 (PRIOR&CONFLICTS).

Set

value data, correction value and irrigation completion (“Done”) value
are displayed on panel C9

C9

C9

C9

C9 (IRRIG STATE).

Information about each program’s previous start condition, date and time
are displayed on panel C16

C16

C16

C16

C16 (PROG LAST START).

Total accumulation value from a previous date is displayed on panel C17

C17

C17

C17

C17

(TOTAL ACCUMUL).
Accumulation value from previous date and activation number for a se-
lected irrigation program are displayed on panel C18

C18

C18

C18

C18 (PROGRAM

ACCUMUL).
Accumulation value from previous date, for selected sector, is displayed in

This manual is related to the following products: