The following are setting requirements for each irrigation program:
- the working period (between start date (day/month) and end date
(day/month)) – use panel S29
S29
S29
S29
S29 (ACTIVE TIMETABLE)
- the working time during a day (between start time and end time) – use
panel S29
S29
S29
S29
S29 (ACTIVE TIMETABLE)
- the cycle work / rest day can be set using panel S30
S30
S30
S30
S30 (WORKDAY)
- the working days in a week – use panel S30
S30
S30
S30
S30 (WORKDAY)
Working time status for each irrigation program, if selected (irrigation
program is in work period of month, day and week) is displayed in panel
C07
C07
C07
C07
C07 (WORK TIME COND).
The percent of irrigation time or set volume can be automatically modified
by the following:
- MANU
MANU
MANU
MANU
MANUAL F
AL F
AL F
AL F
AL FA
AA
AACT
CT
CT
CT
CTOR
OR
OR
OR
OR: This option can be set using panel S44
S44
S44
S44
S44 (IRRI-
GATION CORR). Percentage and corresponding value of time or
volume can be viewed using panel C10
C10
C10
C10
C10 (MAN CORRECTION).
- TEMPERA
TEMPERA
TEMPERA
TEMPERA
TEMPERATURE
TURE
TURE
TURE
TURE: This option can be set using panel S44
S44
S44
S44
S44 (IRRIGA-
TION CORR).
Total correction percentage, time or volume value is displayed on panel
C11
C11
C11
C11
C11 (TOTAL CORRECTION).
In each irrigation program the pre-irrigation and post-irrigation time or
volume value (used to clean the irrigation pipes with pre-irrigation water)
can be set using panel S35
S35
S35
S35
S35 (PRE/POST IRRIG).
Panel C01
C01
C01
C01
C01 (GENERAL INFO) displays the active irrigation program and
active sectors.
The active irrigation program is displayed on panel C03
C03
C03
C03
C03 (SENSORS STATE).
Related data regarding the active irrigation program (active irrigation pro-
gram number, last start condition and current / set repetition number) are
displayed on panel C04
C04
C04
C04
C04 (PROGRAM STATE).
Information about selected irrigation program, priority and irrigation pro-
gram conflict are displayed on panel C08
C08
C08
C08
C08 (PRIOR&CONFLICTS).
Set
value data, correction value and irrigation completion (“Done”) value
are displayed on panel C9
C9
C9
C9
C9 (IRRIG STATE).
Information about each program’s previous start condition, date and time
are displayed on panel C16
C16
C16
C16
C16 (PROG LAST START).
Total accumulation value from a previous date is displayed on panel C17
C17
C17
C17
C17
(TOTAL ACCUMUL).
Accumulation value from previous date and activation number for a se-
lected irrigation program are displayed on panel C18
C18
C18
C18
C18 (PROGRAM
ACCUMUL).
Accumulation value from previous date, for selected sector, is displayed in