Hanna Instruments HI 8050 User Manual
Page 41

41
SET START TIME – S33
Prog 07
07:00 09:20 10:30
12:00 14:00 16:00
SET START TIME S33
If time is selected as the starting trigger for an indexed program, up to six
different starting times within the daily schedule limits (see panel S29
S29
S29
S29
S29 (ACTIVE
TIMETABLE)) can be selected. The program number indexes this panel. This
panel displays and allows the setting of the following parameters:
− PPPPProgram Number
rogram Number
rogram Number
rogram Number
rogram Number - Panel index (used to view settings for all programs).
− Start times
Start times
Start times
Start times
Start times - Six individual (selectable) hour settings for program start
within daily schedule limits for indexed program.
SET PROGRAM REPEATS – S34
Prog 07
Repeats 04
Pause 00:30:00
PROGRAM REPEATS S34
Once a program is triggered it is possible to set it to repeat by using this
panel. The program number indexes this panel. This panel displays and al-
lows the setting of the following parameters:
− PPPPProgram Number
rogram Number
rogram Number
rogram Number
rogram Number - Panel index (used to view settings for all programs).
− Repeats
Repeats
Repeats
Repeats
Repeats - Selectable number of repetitions following the initial execution of
the indexed program.
− Pause - Selectable amount of delay time between repetitions.
PRE/POST IRRIG – S35
Prog 07
PreIrrig: 015000L
PostIrrig: 010000L
PRE/POST IRRIG S35
Prior to after the execution of the indexed program an amount of pre and post
irrigation water can be specified in time or volume. To set irrigation control
mode see panel S55 (IRRIG CTRL MODE). The program number indexes this
panel. This panel displays and allows the setting of the following parameters: