beautypg.com

Hanna Instruments HI 8050 User Manual

Page 25

background image

25

INPUT PASSWORD PANEL

Enter password:

****

This panel is displayed during the password authentication sequence. If this
sequence fails the user will be logged off and the ST

ST

ST

ST

STAR

AR

AR

AR

ARTTTTT panel will be dis-

played. If the password is correct panel C01

C01

C01

C01

C01 (GENERAL INFO) is displayed.

The default password is 0000

0000

0000

0000

0000. See section Setting Password for instructions

on setting this feature.
Although access to the controllers features are denied the functionality of the
controller is not directly affected if a password authentication sequence fails.

CONSUL

CONSUL

CONSUL

CONSUL

CONSULTING P

TING P

TING P

TING P

TING PANELS

ANELS

ANELS

ANELS

ANELS

GENERAL INFO – C01

WORK Anomalies 00

Prog 08 06.4pH

Sect 07 02.1mS 13:15

GENERAL INFO C01

This panel displays the following information from top left:
− Fertigation Controller Functional State (top left corner)

Fertigation Controller Functional State (top left corner)

Fertigation Controller Functional State (top left corner)

Fertigation Controller Functional State (top left corner)

Fertigation Controller Functional State (top left corner) - When

the controller is running it can be in one of the following states: INITIAL-

INITIAL-

INITIAL-

INITIAL-

INITIAL-

IZA

IZA

IZA

IZA

IZATION

TION

TION

TION

TION, ST

, ST

, ST

, ST

, STOP

OP

OP

OP

OP, WORK

, WORK

, WORK

, WORK

, WORK, BL

, BL

, BL

, BL

, BLOCK

OCK

OCK

OCK

OCK..... When the Fertigation Controller is

first powered on the first state is INITIALIZA

INITIALIZA

INITIALIZA

INITIALIZA

INITIALIZATION

TION

TION

TION

TION. In this state the unit

performs internal tests. In ST

ST

ST

ST

STOP

OP

OP

OP

OP state all programs are suspended. Under

normal conditions the functional state is WORK

WORK

WORK

WORK

WORK. In the WORK

WORK

WORK

WORK

WORK state all

irrigation and fertilization programs are executed. If an alarm occurs the
Fertigation Controller enters the BLOCK

BLOCK

BLOCK

BLOCK

BLOCK state until the alarm condition is

corrected. The user can customize the alarm management system behav-
ior using setting panels S36, S38

S36, S38

S36, S38

S36, S38

S36, S38 (pH and EC CONTROL) and panel

S54

S54

S54

S54

S54 (ALARM BEHAVIOR).

− Anomalies (top right corner) -

Anomalies (top right corner) -

Anomalies (top right corner) -

Anomalies (top right corner) -

Anomalies (top right corner) - The anomalies counter represents the

number of alarms triggered since the last reset of the counter. This counter
can be customized and cleared along with all system statistics via setting
panel S65 (ERASE STATISTICS).

This manual is related to the following products: