diameter of the pipe from the main pipe to the sector’s valve, or the
minimum section that appears on that pipe.
NOTE: if the pipes are clogged up the correct computing of the quantity of
water might be impeded!
COUNTER SETTINGS – S57
Fert1
=
1000mL/pulse
COUNTER SETTING S57
This panel allows the setting of the counter factor for the fertilizers. The Fert
field is index of this panel. This panel displays and allows the setting of the
counter factor. For each fertilizer the counter factor can be set in mL/pulse.
PUMPS SELECTION – S58
Pump1 En:Y Prog 07
Pump2 En:Y
Pump3 En:Y
PUMPS SELECTION S58
This panel allows the setting of the pumps (water source) used by an irrigation
program. This panel displays and allows the setting of the following param-
eters:
− Pump1 En
Pump1 En
Pump1 En
Pump1 En
Pump1 En – when set to ‘Y’ the pump 1 is active when the selected
program is running.
− Prog
Prog
Prog
Prog
Prog – the selected program for which the pump setting applies (can be set
only in panel C04 (PROGRAM STATE)).
− Pump2 En
Pump2 En
Pump2 En
Pump2 En
Pump2 En – when set to ‘Y’ the pump 2 is active when the selected
program is running.
− Pump3 En (only for HI8050)
Pump3 En (only for HI8050)
Pump3 En (only for HI8050)
Pump3 En (only for HI8050)
Pump3 En (only for HI8050) – when set to ‘Y’ the pump 3 is active
when the selected program is running.
NOTE: The pump1 is always active.
MOTORIZED VALVES – S59
Max Lit Time: S
Close pH If Idle :Y
Close Fert If Idle:Y
MOTORIZED VALVES S59
This panel allows the setting of the motorized valves used to control the pH