55

displays and allows the setting of the following parameters:
− Disable password - Choosing Y for the “Disable password” option will allow

free access to the Fertigation Controller after every start-up sequence,
while choosing N will enable start-up after which password authorization
will be required to view display panels.

− New password - New password input.

NOTE: The function of the Fertigation Controller is not affected due to a failed
or successful password authorization process during log on.
ERASE STATISTICS – S65

Erase all: -

On overflow: Y

Daily at

hour: 00:01

ERASE STATISTICS S65

With this panel it is possible to erase stored statistics pertaining to controller
function manually, on overflow, or at a certain time. Enter Y (yes) or N (no)
next to the selection or time for daily option.
− Erase all

Erase all

Erase all

Erase all

Erase all - Manual command to erase statistics.

− On overflow

On overflow

On overflow

On overflow

On overflow - This option sets the controller to erase statistics whether their

value overflows.

− Daily at hour -

Daily at hour -

Daily at hour -

Daily at hour -

Daily at hour - Statistics can be erased daily by entering a specific time.

ERASE SETTINGS – S66

Erase program: --

Erase all programs -

ERASE SETTINGS S66

With this panel it is possible to erase the settings of a specific program or all
programs. Erasing settings for an irrigation program provide a very useful
and easy mechanism to set one or all program parameters to default values.
This operation will place a program in a NO

NO

NO

NO

NOT SET

T SET

T SET

T SET

T SET state meaning that it is

disabled. This function is only possible if a program is not active. Once the
command is accepted a delay period of approximately 3 seconds occurs. This
panel displays and allows the setting of the following parameters:
− Erase program - Program number input.

− Erase all programs - Selecting this option (Y (yes) or N (no)) erases the

settings for all nonactive programs.

NOTE: This operation will automatically resets the Fertigation Controller.