Hanna Instruments BL 982411 User Manual

Hanna Instruments Sensors

background image

WARRANTY

Instruction Manual

BL 982411-0
BL 982411-1

Panel-Mounted

ORP Indicators &

Controllers

BL982411-0 and BL982411-1 are panel-mounted ORP
indicators and controllers designed for simplicity of use in a
wide range of industrial applications.
Connections and wiring to electrode, power supply and
contacts are made via the terminal blocks on the rear panel.
The meters are equipped with a BNC socket and accept input
from conventional ORP electrodes.
Other features include: overtime control system, selection of
dosing direction (Rdx/Oxd), one dosing contact, multi-colour
LED for indicating if the meter is in measurement/dosing/
alarm condition, possibility to set (Off-Auto-On switch) dosing
action mode.
Two models are available:
• BL 982411-0 powered at 12 Vdc
• BL 982411-1 powered at 115 or 230 Vac

GENERAL DESCRIPTION

SPECIFICATIONS

Range

0 to 1000 mV

Resolution

1 mV

Accuracy

(@ 20°C/68°F)

±5 mV

Typical EMC Deviation

±5 mV

Calibration

Manual, through CAL trimmer

Dosing Contact

Maximum 2A (fuse protected),

250 Vac, 30 Vdc

Dosing Selection

Rdx or Oxd, selectable on the back panel

Contact Open=Reductant dosage=Relay ON if Measure > Setpoint
Contact Close=Oxidant dosage=Relay ON if Measure < Setpoint
Setpoint

Adjustable, from 0 to 1000 mV

Overtime

Adjustable, typically from 5 to approx. 30 minutes

Power Consumption

10 VA

Installation Category

II

Power supply:

External (fuse protected)

BL932700-0

12 Vdc

BL932700-1

115/230 Vac ; 50/60Hz

Dimensions

83 x 53 x 99 mm (3.3x2.1x3.9”)

ACCESSORIES

Remove the instrument from the packing material and
examine it carefully. If any damage has occurred during
shipment, immediately notify your Dealer or the nearest
Hanna Customer Service Center.
Each meter is supplied with:
• Mounting brackets
• Instruction manual
Note: Conserve all packing material until the instrument

has been observed to function correctly. Any defective
item must be returned in its original packing.

Dear Customer,
Thank you for choosing a Hanna product.
This manual will provide you with the necessary information
for the correct operation of the meter. Please read it carefully
before using the instrument.
If you need additional technical information, do not hesitate
to e-mail us at [email protected].
These instruments are in compliance with the

directives.

PRELIMINARY EXAMINATION

ORP SOLUTIONS
HI 7020M/L ORP test solution (200-275 mV), 230/500 mL
HI 7021M/L ORP test solution (240 mV), 230/500 mL
HI 7022M/L ORP test solution (470 mV), 230/500 mL
HI 7091M/L Pretreatment Reducing Solution, 230/500 mL
HI 7092M/L Pretreatment Oxidizing Solution, 230/500 mL

OTHER SOLUTIONS
HI 70300M/L Electrode storage solution, 230/500 mL bottle
HI 7061M/L Electrode cleaning solution for general pur-

poses, 230/500 mL bottle

ORP ELECTRODES
HI 3214P/2 BNC-type, platinum, double-junction, plastic-

body with 2m (6.6’) cable

HI 2003/5

Heavy-duty, BNC-type, platinum, double junc-
tion, plastic-body with 5m (16.5’) cable

HI 2012/5

Heavy-duty, BNC-type, platinum, double junc-
tion, plastic-body with 5m (16.5’) cable

EXTENSION CABLES FOR SCREW-TYPE ELECTRODES,
SCREW TO BNC CONNECTOR
HI 7855/5

Extension cable 5 m (16.5') long

HI 7855/10 Extension cable 10 m (33') long

OTHER ACCESSORIES
BL PUMPS Dosing Pumps with flow rate from 1.5 to

20LPH

HI 6050

Submersible electrode holder, 60 cm (24”)

HI 6051

Submersible electrode holder, 110 cm (43”)

HI 6054B

Electrode holder for in-line applications

HI 6054T

Electrode holder for in-line applications

HI 710005

12 Vdc power adapter, US plug

HI 710006

12 Vdc power adapter, European plug

HI 710012

12 Vdc power adapter, Australian plug

HI 710013

12 Vdc power adapter, South-African plug

HI 710014 12 Vdc power adapter, UK plug
HI 731326

Calibration screwdriver (20 pcs)

HI 740146 Mounting brackets
HI 7871

Level Controller (min and max)

HI 7873

Level Controller (min, max and overflow)

Recommendations for Users
Before using these products, make sure that they are entirely suitable for the environment
in which they are used. Operation of these instruments in residential areas could cause
unacceptable interferences to radio and TV equipment. Avoid touching the electrode sensor at
all times. During operation, ESD wrist straps should be worn to avoid possible damage to
the electrode by electrostatic discharges. Any variation introduced by the user to the supplied
equipment may degrade the instrument’s EMC performance. To avoid electrical shock, do
not use these instruments when voltages at the measurement surface exceed 24 Vac or 60
Vdc. To avoid damages or burns, do not perform any measurement in microwave ovens.

ASSEMBLING VIEW

These instruments are warranted for two years against defects in work-
manship and materials when used for their intended purpose and
maintained according to instructions. Probes are warranted for six months.
This warranty is limited to repair or replacement free of charge.
Damages due to accident, misuse, tampering or lack of prescribed main-
tenance are not covered. If service is required, contact the dealer from
whom you purchased the instrument. If under warranty, report the model
number, date of purchase, serial number and the nature of the failure. If
the repair is not covered by the warranty, you will be notified of the
charges incurred. If the instrument is to be returned to Hanna Instruments,
first obtain a Returned Goods Authorization Number from the Customer
Service department and then send it with shipment costs prepaid. When
shipping any instrument, make sure it is properly packaged for complete
protection.