Boiler specification, Boiler design – Glow-worm Betacom C User Manual
Page 8
8
Boiler
Specification
Boiler Design
These boilers are designed for use as part of a sealed water
central heating system with fully pumped circulation. The
pump, expansion vessel and associated safety devices are all
fitted within the boiler.
14
34
3
BOILER SPECIFICATION
24c
30c
Lift weight
37 kg (82 Ib)
38 kg (84 Ib)
Total weight (installed)
40 kg (88 Ib)
41 kg (90 Ib)
Gas connection Ø O.D.
22mm. copper
22mm. copper
Heating flow and return connection Ø O.D.
22mm. copper
22mm. copper
Domestic hot water connection Ø O.D.
15mm. copper
15mm. copper
Condensate connection Ø I.D.
21.5mm. plastic
21.5mm. plastic
Safety valve discharge connection Ø O.D.
15mm. copper
15mm. copper
Heating circuit safety valve (preset)
3.5 bar (53.5 Ibf/in2)
3.5 bar (53.5 Ibf/in2)
Heating system minimum pressure
0.8 bar (11.6 Ibf/in2)
0.8 bar (11.6Ibf/in2)
Heating system nominal pressure
1.5 bar (21.7 Ibf/in2)
1.5 bar (21.7 Ibf/in2)
Maximum domestic water supply pressure
8 bar (116 Ibf/in2)
8 bar (116 Ibf/in2)
Minimum domestic water supply pressure
0.25 bar (3.6 Ibf/in2)
0.25 bar (3.6 Ibf/in2)
Maximum domestic hot water temperature
64ºC
64ºC
Maximum central heating temperature
85ºC
85ºC
Maximum domestic hot water output at 35
o Δ T
9.4
L/min.
10.5
L/min.
Expansion vessel capacity
7 litres (1.53 gallons)
8 litres (1.76 gallons)
Expansion vessel pre-charge pressure
1.0bar (14.6 Ibf/in2)
1.0bar (14.6 Ibf/in2)
Minimum flow rate around the
776 L/hr.
1032 L/hr.
central heating circuit at 35 rise
Electrical supply
230V~50Hz fused 5A
230V~50Hz fused 5A
Maximum power comsumption
220 Watt
220 Watt
EN60529 IP clasification
IPX4D
IPX4D
Internal fuse rating on main PCB
2A
2A
Gas supply (governed meter only - NG)*
G20 - NG /G31 - Propane
G20 - NG /G31- Propane
Gas category
II
2H3P
II
2H3P
Inlet gas working pressure - NG
20 mbar
20 mbar
Heat input maximum
25.7 kW.
28.5 kW.
Heat output maximum
24.7 kW.
27.6 kW.
Heat input minimum
11 kW.
11 kW.
Heat output minimum
10.2 kW.
10.2 kW.
Usefull efficiency at 100% load
96%
96.8%
Usefull efficiency at 30% load
102.4%
103.3%
Burner injector NG / LPG (G31)
1.20 mm / 0.75mm
1.15 mm / 0.75mm
Burner pressure maximum NG**
12.5 mbar
14 mbar
Burner pressure minimum NG
2.5 mbar
2.3 mbar
SEDBUK rating
Band B 86.0%
Band 86.4%
NOx
Class 3
Class 3
Flue Type
C12-C32-C42-C52
C12-C32-C42-C52
* See Commissioning section for NG (G20) to LPG (G31) conversion
** Installation to (G31) Propane is by conversion kit only
The appliance has a built in frost protection device that
protects the boiler from freezing.
Once the controls are set the boiler operates automatically.