10 flue fitting – Glow-worm Betacom C User Manual

Page 28

background image

28

Diagram 9.16

12847

Diagram 9.17

14472

9 Standard Flue - Length, Preparation and Installation

9.10 Flue Fitting

Remove the flue elbow.

Separate the flue duct from the terminal by twisting to release

the terminal catch, then pull out of the retaining seal, refer to

diagram 9.16.

The flue duct cutting length (L + 11mm.) is shown in diagram

9.16.

The air duct should be cut at the opposite end to the terminal

The plastic flue duct MUST be cut at the opposite end to the

terminal catch.

The plastic flue duct extensions MUST be cut at the opposite

end to seal.

The cut ducts must be de-burred and all filings and debris

removed.

Insert the flue duct into the air duct terminal assembly,

remembering to engage the catch within the terminal.

NOTE: If the seals require lubricant to ease installation, do

not use mineral oils or grease, only silicon grease or water is

recommended.

Fit the sealing collar behind the locating lugs on the flue

terminal, see diagram 9.17.

Push the flue assembly into the wall, externally or internally,

initially until the end of the assembly protrudes a short way

from the inside face of the wall. This will enable the internal

trim ring (if required) to be positioned and allow the flue

assembly to be drawn back into the flue elbow.

Secure the flue elbow in position on top of the boiler with four

torque headed screws supplied.

Draw the flue assembly from wall and engage the flue duct

into the elbow and butt fit between the air duct and flue elbow.

Ensuring the correct alignment of the terminal.

Fit the securing collar into position, mark through two of the

pre drilled holes in the securing collar. Remove securing

collar and drill two 3mm diameter holes one in the elbow and

one in the air duct, take care not to pierce the inner flue duct.

Fit the securing collar and secure with screws provided, see

diagram 9.17.

Slide the internal trim ring back against the wall, securing in

place with a small amount of sealant if required.

NOTE: If the air and flue ducts have been correctly cut to the

instructions the sealing collar should fit flush with the outside

wall, check this.