beautypg.com

14 replacement of parts, 15 expansion vessel, 16 overheat safety thermostats – Glow-worm Betacom C User Manual

Page 62: 17 pressure safety relief valve

background image

62

14 Replacement of parts

14.15 Expansion vessel

For access, refer to section 14.1.

Drain the boiler circuit, refer to section 14.2.

Refer to diagram 14.16.

Disconnect the flexible pipe coupling on expansion vessel.

Release and remove the nut securing the expansion vessel to

the boiler.

Remove the side panels.

Remove the air pressure switch, refer to section 14.6.

Remove the flue if required.

Lift the vessel out of boiler from the gap over the chassis

and fit the replacement vessel to the boiler in reverse order

to removal, ensuring that sealing washer is fitted to pipe

connection before tightening, replace the washer if necessary.

Using a pressure gauge, ensure that expansion vessel charge

pressure is 0•5bar (7•5psi)

Open the isolating valves on the flow and return connections,

refill, vent and pressurise the boiler ensuring all joints are

sound.

14589

14588

14587

Diagram 14.16

Diagram 14.18

Diagram 14.17

14.16 Overheat safety thermostats

For access, refer to section 14.1.

Remove the front panel, combustion chamber cover and right

side panel.

Refer to diagram 14.17.

Locate the overheat safety thermostat at the front left hand

side of the boiler and on the right hand side of the primary

heat exchanger.

Disconnect the electrical connections from the thermostat.

Unclip the thermostat from the pipe.

Fit the replacement thermostat in reverse order of removal.

14.17 Pressure safety relief valve

For access, refer to section 14.1.

Drain the boiler circuit, refer to section 14.2.

Refer to diagram 14.18.

Disconnect the discharge pipe on the outlet of the safety relief

valve.

Unscrew to remove the safety relief valve from the R.H.

hydroblock and retain the o-ring for use on reassembly,

replace as necessary.

Fit the replacement safety relief valve in reverse order to

removal and refill, vent and pressurise boiler ensuring all joints

are sound.

FLEXIBLE PIPE

CONNECTION

PRESSURE

SAFETY RELIEF

VALVE

UNSCREW

TO REMOVE

R.H. HYDRAULIC

BLOCK

DISCHARGE

PIPE

SECURING NUT

OVER HEAT SAFETY

THERMOSTAT

ELECTRICAL

CONNECTIONS