beautypg.com

14 replacement of parts, 10 pump body – Glow-worm Betacom C User Manual

Page 58

background image

58

14 Replacement of parts

14.10 Pump body

For access, refer to section 14.1.

Remove the motor as described in section 14.9.

Remove the low water pressure sensor refer to section 14.11.

Remove the secondary heat exchanger as described in

section 14.12.

Refer to diagram 14.7.

Remove the expansion vessel pipe by removing the clip on

the pump body. (clip at the rear, see diagram 14.8.

Remove the pressure gauge connection and electrical

connection form the R.H.hydroblock.

Disconnect the union nuts (pressure safety relief valve and

pump outlet).

Refer to diagram 14.9.

Remove the fixing screws from the pump and R.H.hydroblock

at the bottom of the boiler.

Remove the pump assembly.

Refer to diagram 14.10.

Remove the pump body, automatic air vent and brass union

connector from the R.H. hydraulic assembly by releasing the

clips. Fit these to the replacement pump body.

Fit the replacement pump body and associated parts in

reverse order ensuring that all sealing washers are sound and

fitted correctly and the polarity of the electrical connections

are correct.

Open the isolating valves on the low and return connections,

refill, vent and re-pressurise the system ensuring all joints are

sound.

14583

14562

Diagram 14.8

Diagram 14.9

Diagram 14.10

Diagram 14.7

ELECTRICAL

CONNECTION

PUMP

BODY

PUMP

BODY

PUMP

BODY

EXPANSION

VESSEL

PIPE

R.H. HYDRAULIC

ASSEMBLY

CLIP

CLIP

CLIP

CLIP

CLIP

SECURING

SCREWS

SECURING

SCREW

SECURING

SCREW

14579

14581

BRASS UNION

CONNECTOR

AUTOMATIC

AIR VENT

PRESSURE

GAUGE

CONNECTION

UNION

NUT

UNION

NUT