9.2 Horizontal Telescopic Flue - A2043600

Refer to diagram 9.2 for kit contents.

9.3 REAR Flue

If a wall thickness is between 210mm min. to 420mm max.

then the flue can be used without extensions.

T

emporarily

secure the

flue elbow, measure the distance

from the outside wall to the butt joint, see diagram

9.4.

If

the measurement ‘Y’ exceeds 525mm, then the appropriate

length of extension pipe is required.

If the dimension is less than 315mm DO NOT cut the flue, it

can project to a maximum of 600mm, refer to diagram 9.5. If

this is not desirable then a Standard flue MUST be used and

cut to length.

9.4 SIDE Flue

T

emporarily

secure the

flue elbow, measure the distance

from the outside wall to the butt joint, see diagram 9.6. If

the measurement ‘Y’ exceeds 525mm, then the appropriate

length of extension pipe is required.

If the dimension is less than 315mm DO NOT cut the flue, it

can project to a maximum of 600mm, refer to diagram 9.5. If

this is not desirable then a Standard flue MUST be used and

cut to length.