10 electrical connection, 3 system controls 230v, 4 electrical connections - testing – Glow-worm Betacom C User Manual

Page 37

background image

37

230V ROOM

THERMOSTAT

CONNECTION

ON PRINTED

CIRCUIT BOARD

230V ROOM

THERMOSTAT

49

50

X20

10 Electrical Connection

ON

30

40

50

60

70

80

90

bar

14539

14538

14479

14637

Diagram 10.3

Diagram 10.4

Diagram 10.5

Diagram 10.6

10.3 System Controls 230V

If a mains voltage thermostat is to be used.

Unclip the two front retaining clips on the controls fascia, see

diagram 10.3.

Unclip and carefully pull down the control circuit board cover,

see diagram 10.4. to access the mains voltage connection

located on the printed circuit board, see diagram 10.5.

On connection of a mains voltage room thermostat to the

boiler, the bridge wire on factory fitted plug must be cut to fit a

connector block.

NOTE: Mains powered thermostats must be connected

directly to the mains circuit board as indicated in diagram

10.6.

NOTE: Ensure that the polarity of the mains connection is

correct as reversed polarity may cause the appliance to

malfunction.

NOTE: While the boiler’s main pcb, pump, three-way valve

and gas valve are supplied at 230V AC., all other components

and associated circuits are supplied at low voltage.

NOTE: When re-assembling, take care NOT TO TRAP the

cables and wires.

NOTE: Connection to the mains electrical supply must be

maintained at all times in order to provide domestic hot water,

frost protection and pump over-run facility.

Ensure that the boilers electrical supply is not interrupted by

any external controls.

10.4 Electrical Connections - Testing

Carry out preliminary electrical system checks prior to making

the final connection as below:

1. Test insulation resistance to earth of mains cables.

2. Test the earth continuity and short circuit of cables.

3. Test the polarity of the mains.

RETAINING CLIPS

BRIDGE PLUG

RETAINING CLIPS

CONTROLS FASCIA

CONTROLS CIRCUIT

BOARD COVER

PRINTED CIRCUIT

BOARD