Copper Tests: Using the Main Menu

68

FTB-610

Application Settings

Standard

The Standard tab allows you to set Measurement unit and Test Parameter
Preset values.

The page allows you to set the following parameters:

Standard Selection

Standard allows you to specify if the copper tests should conform to
the ITU (International Telecommunications) or ANSI (American
National Standards Institute) standard.

Note: Selecting the Standard resets the default Measurement Units, Label

Customization, and Test Parameters Preset for the page.

Measurement Units

Distance lists the measurement units for distance in feet or meters.

Temperature lists the measurement units for temperature in
F (Fahrenheit) or C (Celsius).

Level lists the units of power level in dBm or dBRN.

Capacitance lists the units of capacitance for Tip and Ring in
(nF/km or nF/mi).