background image

TDR Test

196

FTB-610

Manual TDR

Save/Load Trace(s)

The Save/Load Trace(s) button opens a page which allows you to
configure parameters to load and save a single trace or Trace Group.

To set the parameters:
1.
From the Manual TDR page, select Save/Load Trace(s) to open the

page.

2. In the Save tab, select the parameters as required.

3. Click Save button to confirm and/or Close button to exit the page.

4. In the Load tab, select the parameters as required.

5. Click Close to confirm and close the page.

Save tab

Storage Location allows you to select where to save your results:
to a USB or the internal memory.

Trace lists the single TDR trace or Trace Group to save.

File Name displays the automatically configured file name or you
can enter a new one.

Save button confirms your selections.