beautypg.com

EXFO FTB-610 Wideband Copper Test Module User Manual

Page 213

background image

RFL Test

Copper Test

205

RFL-2-Wire

The page displays single pair RFL test results. Based on the cable
condition, corresponding values are added into the diagram at their
specific positions. Test result units are dependent on Standard in
Setup/Application Settings.

Distance to strap (DTS).

Resistance to strap (RTS).

Distance from fault to strap (DFTS).

Resistance from fault to strap (RFTS).

Resistance to fault (RTF).

Distance to fault (DTF).

Faulted cable (FC).

Resistance at Fault (Rf) is the ohms of the fault only.

Voltage at fault (Vf).

If the test reports that it cannot detect the strap when the measured
loop resistance is >10 k Ohm, this may mean:

There is no strap connected.

There is a strap, but the cable is too long and has a loop resistance
>10 k Ohm.

There is a strap, but there is a high resistance fault or open in the
cable.

The connection (leads or strap) may be faulty.

The resistance test may be used to troubleshoot this problem.

Fault Status displays the status of the RFL test.

Test Status displays the current state of measurement or an error
message.