beautypg.com

EXFO FTB-610 Wideband Copper Test Module User Manual

Page 284

background image

Impulse Tests

276

FTB-610

Impulse Scope Test

The page opens to the time-domain graph by default, with the frequency
domain graph insert, and displays the following parameters:

Edit Parameters button opens a new page that allows you to set the
test parameters.

Edit Thresholds button opens a new page that allows you to set the
Impulse Scope Threshold.

Graph Settings button opens a new page that allows you to set
parameters for the Impulse Scope main graph and graph insert. Here,
you may also disable the graph insert, and choose to view either the
time or frequency domain graph.

Save Test button opens a new page that allows you to save a snapshot
of test results into a result file. Refer to Save Test on page 74 for more
information.

Voltage Threshold determines when impulse events are displayed or
captured (trigger level) based on the Peak voltage level of the event(s).
The Voltage Detection Level, set in the Threshold page above, is
displayed.

Capture Window provides a drop-down list that allows you to select
the x-axis display window width.

IST (Impulse Separation Time) specifies the time interval between
successive impulses. Some impulse events comprise many sub-pulses
or a pulse-train. Use a larger IST to capture longer events of many
sub-pulses, or a smaller IST between events to capture fast sub-pulses
as separate impulse events.

Toggle

graph control icon allows you to switch between graphs on

the page, making the graph insert larger and the main graph into the
graph insert. You can also double tap the small windows to toggle
between large and small graphs.