Multimeter Tests

140

FTB-610

Current Test

Setting Threshold Values

The Test Threshold page allows you to set the Threshold Current for
each pair.

To set the Threshold values:
1.
From the Copper main menu Test Groups, select Multimeter test

.

2. From the Tests menu, select Current test.

3. Tap Continuous DC or Continuous AC tab for which you want to set

the Threshold values.

4. Tap Edit Thresholds button to open the Test Thresholds page.

5. Set the Threshold values as required.

6. Tap Close to confirm and exit the page.

The page allows you to set the following parameters:

Threshold is the threshold limit for each pair: Maximum, Minimum, or
None.

Threshold Current sets the threshold value.