beautypg.com

EXFO FTB-610 Wideband Copper Test Module User Manual

Page 103

background image

Pair Detective Test

Copper Test

95

Pair Detective

The page allows you to set the following parameters:

Cable Type allows you to select a cable entry (with its associated
parameters) from the current Cable Book, to use for testing. The
selection is not saved when leaving the test. The current Cable Book
entry is shown by default.

Cable Fill read-only entry is the type of material the cable is filled with:
Aircore, Jelly, Pulp, 5 PR, or 2 PR. Setup in the Cable Book.

Velocity of Propagation read-only entry is the velocity of propagation
for the cable as a ratio of the speed of light. Setup in the Cable Book.

Cable Temperature allows you to change the temperature of the cable
under test in either degree C or F.