Technical Specifications
310
FTB-610
COPPER SPECIFICATIONS
a, b, c
(continued)
Single-ended frequency response (attenuation)
d
Distance range
100 m to 5000 m (300 ft to 16000 ft)
Frequency range
4.3 kHz to 30 MHz
Frequency uncertainty (accuracy)
±(50 ppm + 1 digit)
Level uncertainty (accuracy)
±2 dB typical for 2.2 MHz and 8 MHz ranges
±3 dB for VDSL2-12 and VDSL2-17
±4 dB for VDSL2-30 ranges
Resolution
0.1 dB
Horizontal scale
ADSL2+ = 2.208 MHz, VDSL2-8 = 8 MHz, VDSL2-12 = 12 MHz,
VDSL2-17 = 17.66 MHz, VDSL2-30 = 30 MHz
Vertical scale
0 dB to 100 dB
Resistive fault location (RFL)
Test type
Single pair (two wire) and separate good pair (four wire) and Küpfmüller (K-Test)
Fault detection
0 to 20 M
1
Resolution
Three digits
Loop resistance
10 k
1maximum
Multiple cable sections
Five (includes gauge and temperature setting)
Fault location
Total resistance, near-end to fault resistance, fault to strap resistance (three
significant digits, least significant digit 0.1
1).
Total length, distance to fault, distance from fault to strap
(three significant digits, least significant digit 1 m)
Uncertainty (accuracy)
±(0.1
1 + 1 % x RTS)
K-Test uncertainty (accuracy)
± (1.0
1 + 1 % RTS + (Rf1 + Rf2)/10 M1) - double fault
± (1.0
1 + 1% RTS) - single fault
Notes
a. Subject to change without notice.
b. Typical, at 23 °C ± 3 °C, on batteries, with no USB connection.
c. Specifications based on 24 AWG (PE 0.5 mm) cabling.
d. Specification based on 1 kft 24 AWG cabling. Range depends on cable type and condition.
TECHNICAL SPECIFICATIONS
Display
Color touchscreen, 800 x 480 TFT, 178 mm (7 in)
Interfaces
Two USB 2.0 ports
RJ45 LAN 10/100/1000 Mbit/s
Fiber inspection probe connector port (video)
Built-in Bluetooth and Wi-Fi (hardware option)
Five-color coded 2 mm analog safety shrouded line interfaces
Storage
8 GB internal memory (flash)
16 GB internal memory (flash), optional
Batteries
Rechargeable lithium-ion batteries
Operating time: 4.75 h (typical with extended battery)
GENERAL SPECIFICATIONS (MODULE ONLY)
Size (H x W x D)
130 mm x 252 mm x 56 mm (5
1
/
8
in x 9
15
/
16
in x 2
3
/
16
in)
Weight
0.93 kg (2 lb)
Temperature
operating
storage
0 °C to 40 °C (32 °F to 104 °F)
a
–40 °C to 70 °C (–40 °F to 158 °F)
Note
a. DC voltage, isolation resistance, VF and WB receiver = 0
o
C to 45
o
C (32
o
F to 113
o
F).