EXFO FTB-610 Wideband Copper Test Module User Manual
Page 75

Copper Tests: Using the Main Menu
Copper Test
67
Application Settings
Capacitance Measurement is either 3 Terminal or 2 Terminal. The
latter method measures the capacitance across the 2 terminals
specified (either T-R, T-G, R-G or A-B, A-E, B-E), whereas the 3 Terminal
method measures the capacitance across the 2 terminals specified,
and shorts the remaining (or unspecified) terminal to G/E.
Note: In order to correctly determine cable length by using the capacitance
measurement, the Cable Book must contain both 3/2 Terminal values.
Test Startup Mode lists the test startup type:
Auto (default) automatically starts a test when you select the
respective icon from the test sub-menu.
Manual requires that you tap the Start button on the Main Menu to
start a test.
Result File Storage Location allows you to select where to save your
results: to a USB or the internal memory.
Report Format is HTML, MHTML, XML, or PDF as the generated report
format.
Prompt To Save Results allows you to enable popup confirmation
messages before leaving a test and not saving results, by checking the
box.
Show Connection Diagram On Test Startup allows you to enable the
hookup diagram upon startup by checking the boxes of the following
tests:
Xtalk
Station Ground
NEXT