Multimeter 2 Tests

Copper Test

185

Station Ground

However, you can check the connection diagram at any time by
tapping Hookup Diagram in the main Station Ground window. In this
case, the test will not automatically start when you tap the OK button to
close the Confirmation window.

Setting Threshold Values

The Test Thresholds page allows you to configure resistance thresholds
for the Station Ground test.

To set the threshold values:
1.
From the Copper main menu Test Groups, select Multimeter 2 test

.

2. From the Tests menu, select Station Ground to start the test.

3. Tap Edit Thresholds button to open the Test Thresholds page.

4. Set the threshold values as required.

5. Tap Close to confirm and exit the page.