RFL Test

206

FTB-610

RFL-4-Wire

RFL-4-Wire

The RFL-4-Wire or separate good pair test allows you to determine the
distance to a short, ground, or battery cross on a faulty cable conductor
using two separate good cable conductors.

Connect a strap from the faulted wire to both conductors of the good pair.

The connection diagram shows you how to connect the cables to the unit.

Note: Results are more accurate but less forgiving than a 2-wire setup because

the 4-wire setup requires you to connect the faulted wire conductor to the
Ring (red) jack only.

To access RFL-4-Wire Test:
1.
From the Copper main menu Test Groups, select RFL test

.

2. From the Tests menu, select RFL test to start the test.

3. Tap RFL-4-Wire tab to open the window.