Echelon LonTal Stack User Manual
Page 237
LonTalk Stack Developer’s Guide
225
LID#
Description
36
The program ID found in the XIF file seems malformed and cannot
be used to produce the niAppinit data
Use the LonTalk Interface Developer utility and the Standard
Program ID calculator to produce a good program ID record. Delete
all intermediate files. Re-run the LonTalk Interface Developer
utility in Trace verbosity mode and carefully examine the LonTalk
Interface Developer utility Summary window to determine the root
cause of the failure. If the problem persists, contact Echelon
technical support, submitting all files produced by the LonTalk
Interface Developer utility when running in Trace verbosity level.
42
A type definition cannot be generated –the type definition has more
elements than expected
Delete all intermediate files. Re-run the LonTalk Interface
Developer utility in Trace verbosity mode and carefully examine the
LonTalk Interface Developer utility Summary window to determine
the root cause of the failure. If the problem persists, contact Echelon
technical support, submitting all files produced by the LonTalk
Interface Developer utility when running in Trace verbosity level.
46
One or more configuration properties implemented within a file are
present, FTP or DMF must be implemented
Alternatively, you can declare configuration properties as
configuration network variables.
47
The file transfer protocol (FTP) and direct memory files (DMF) access
mechanisms are mutually exclusive
49
The FTP server interface is partially implemented, missing the
specified member of the node object
50
Data files and file directory are too big for the available space.
Available: bytes) data files, or by sharing CP, or implement FTP. 51 Malformed XML data (cannot convert to expected type) 52 The specified application framework type is unknown 53 No target framework has been supplied, or the requested framework 54 No code generator found for the selected target framework
[LID#50]
Possible remedies: reduce the size of files by removing extraneous
is not registered with, or not known to, the Builder