FIG 179

1. Remove the casefeed tube FIG 179.

FIG 180

2. Remove the casefeed adapter FIG

180.

FIG 181

3. To replace the casefeed arm bushing

first raise the platform. Remove the
casefeed arm bushing (currently
installed in your machine) and
replace it with the new one FIG 181.

4. After installing the new casefeed arm

bushing, install the new casefeed
adapter.

FIG 182

5. Reinstall the casefeed tube by placing

the casefeed tube into the casefeed
adapter and snapping it into the metal
clamp FIG 182.

Note: One end of the casefeed tube is

beveled and one end is squared off.
Insert the squared end of the tube
(down) into the top of the casefeed
adapter.

FIG 183

Step 14) Case insert slide cam – turn

around FIG 183:

The case insert slide is reversible. The

long side of the cam (see arrow “A” FIG
184
) is for pistol and the short side of the
cam (see arrow “B” FIG 184) is for rifle. As
a reference, any case as long or longer than
.223 Rem. will require that the short (rifle)
side of the cam be used. Reverse the case
insert slide cam only if your caliber conver-
sion requires it.

FIG 184

FIG 185

1. Using a 5/32” Allen wrench, remove

the cam screw FIG 185 and reverse
the case insert slide.

FIG 186

2. FIG 186 Insure that the back side of

the cam is flush with the cam slide.

3. Replace the cam screw and snug it.

39

B

A