beautypg.com

Fig 154 – caliber conversion chart sample – Dillon Precision XL 650 User Manual

Page 34

background image

1. How to use the Caliber

Conversion Chart:

To explain the Caliber Conversion

Chart we are going to compare the pistol
caliber of .38 Spl. to the rifle caliber of
.30-06 FIG 154.

By comparing the two columns, you can

see which parts need to be changed. In this
comparison, .38 Spl. vs. .30-06, you can
see that none of the part numbers match up,
therefore, all of the those parts would need
to be changed. This, however, is not always
the case. If you compare .30-06 to
.308/7.62 Nato, you’ll find that they are
exactly the same. Another example would
be .38 Spl. vs. .357 Magnum. As you can
see, they too are identical. Some caliber
comparisons will show that only a couple
of parts are different – in this case, instead
of ordering an entirely new caliber conver-
sion kit, you have the option of ordering
only those parts needed to complete your
caliber conversion.

2. Conducting the Caliber

Conversion

(The following steps are in the sequential
order in which the caliber conversion is to
be conducted):

Note: Included in the following is a com-

plete list of all the items that need to
be considered when conducting a
caliber conversion. This is not a list
of all the items that will need to
changed or readjusted – this is a
complete list of all the items that
may need to be changed or re-
adjusted. The items that need to be
changed or readjusted will depend
on the caliber your XL 650 is cur-
rently set up to load and the caliber
you’re changing to.

Step 1) Remove the cases from the
machine:

1. Turn off the casefeed system

2. Remove the remaining cases from the

casefeed tube and the casefeed bowl.

Step 2) Remove the powder from the

powder measure:

Depending on the caliber change, you

may have to change powders and/or the
powder bar. If so, you’ll need to empty the
powder from the powder measure.

FIG 155

1. Disconnect the failsafe rod FIG 155.

FIG 156

2. Loosen the two powder measure

clamp screws FIG 156.

3. Remove the powder measure and

empty the powder back into the pow-
der can.

4. Manually cycle the powder bar to

ensure the powder measure is empty.

5. If you need to change powder bars

refer to Step 19.

FIG 157

Step 3) Remove the toolhead FIG 157:

1. Disconnect the failsafe rod FIG 155.

2. Remove the toolhead pins and slide

the toolhead out.

Step 4) Remove the shellplate:

Remove the shellplate only if you need to

either, change the shellplate for a different
caliber shellplate, or if you need to remove
the primer system (such as when emptying
the primers from the primer system).

FIG 158

1. Using a 1/8” Allen wrench loosen the

shellplate set screw FIG 158. The
shellplate set screw is located on the
left side of the mainshaft just below
the shellplate platform. Do not
remove the screw, just loosen it about
a half turn.

35

Caliber Conversion Section

FIG 154 – Caliber Conversion Chart Sample

Caliber

Complete

Shellplate

Locator

Funnel

Station 1

Casefeed

Arm

Body

Casefeed

Primer

Powder

Conversion

Number

Button

Locator

Adapter

Bushing

Bushing

Disc

System Check Rod

38 Spl

21098

(2) 13430

(2) 14062 (D) 13599

(2) 13563

(Orange) 13386

(Red) 13403

(Sm38) 13384 (LP) 21072

Sm

Med

.30-06

21094

(1) 13204

(1) 13930 (B) 13587

(1) 13595

(Black) 13541

(White) 13661 (Med) 13604

(LR) 21075

Lg

Med