YSI 6200 DAS USER Manual
YSI/Massachusetts 508.748.0366, Fax 508.748.2543 Page 5-1
Section 5
Connecting Sensors to the Field Station
5.1 Introduction
There are five standard sensor packages that may be ordered for use with the 6200 DAS. If you
performed the checkout setup described in Section 2, you should be familiar with these sensors.
The barometer is factory installed. The other four sensors are connected to the 6200 DCP
enclosure using weatherproof MS-style connectors that plug into the bottom of the enclosure and
are secured by a threaded nut. Be careful not to cross-thread the retaining nut. Use your fingers
to tighten the nut. Do not use tools to tighten. Refer to the list below for general reference and
to Figure 5.1 to determine the location of each sensor input connector. If you are not installing
one of the sensors below, be certain to leave the waterproof cap in place and securely attached.
♦
Meteorological (MET) Suite (wind speed and direction, RH and air temperature)
♦
Pyranometer (solar radiation sensor)
♦
Rain Gauge (tipping bucket design)
♦
Sonde (multiparameter water quality, including temp, DO, conductivity, pH and more)
♦
Barometer (installed within the 6200 DCP at the factory, no connector required)
Figure 5.1 6200 DCP External Connectors for Sensor Inputs
MET Suite
Rain Gauge
Pyranometer
RF Connector (N-Type)
Barometer Vent
For conduit fittings..
AC, solar, and phone lines
6-Series Sonde
bottom view of enclosure
Front Cover
Grounding Terminal