TeeJet TASC-6600 User Manual
Page 9
1-3
TASC-6000, 6300, 6600
98-05010
Rev. - 1
1.4.2 DISPLAY SELECTOR FUNCTIONS IN SET UP MODE
(Refer to Appendix D for these switch functions in "Handgun Mode".)
MID-TECH
MIDWEST TECHNOLOGIES, INC.
CHEMICAL APPLICATORS
1
2
3
ON
OFF
Alt.-
Rate
TASC-6600
TOTAL APPLICATION
SPRAYER CONTROL
1
2
3
4
5
6
7
8
9
BOOMS
4
5
6
.
-Ac
Flow
RATE
Gal./
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Chem. Applied
Test
Speed
Prime
Total Applied
Chem. Rate
Appl. Rate
CHEMICALS
CARRIER
Scan
MID-TECH
MIDWEST TECHNOLOGIES, INC.
ON
OFF
Alt.-
Rate
TASC-6600
TOTAL APPLICATION
SPRAYER CONTROL
1
2
3
4
5
6
7
8
9
BOOMS
6
Ac
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Chem. Applied
Test
Speed
Prime
Total Applied
Chem. Rate
Appl. Rate
CHEMICALS
CARRIER
Scan
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Chem. Applied
Test
Speed
Prime
Total Applied
Chem. Rate
Appl. Rate
CHEMICALS
CARRIER
Scan
MID-TECH
MIDWEST TECHNOLOGIES, INC.
Ac
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
MID-TECH
MIDWEST TECHNOLOGIES, INC.
-Ac
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
OFF
SET- UP
DEC.
ON
OPERATE
INC.
SPEED: Ground Speed Override (GSO) Value
AREA: Accumulated Area #2.*
CHEMICALS CHEM. APPLIED: Injection pump calibration number for the pump that is turned ON. Err means no
pump is selected or more than one pump is selected.**
CHEMICALS CHEM. RATE: The volume per acre to be delivered by an individual injection pump. Each pump must
be selected ON in sequence. Two rates are programmable, one in each position of the injection pump switch: ON -
Standard Rate or Alt. Rate - Alternate Rate. Err means no pump is selected or more than one pump is selected.**
CHEMICALS % RATE: The percent of change applied to all active injection pump application rates for each actuation
of the INC/DEC switch.**
CARRIER APPL. RATE: The target application rate of the main carrier, including injected chemical.**
CARRIER TOTAL APPLIED: The flow meter calibration number**
WIDTH: Individual boom section widths. The display cycles through the individual boom sections sequentially, unless
a particular boom switch is activated.**
DISTANCE: The current distance calibration number.**
PRIME: The prime volumes for the pump that is turned ON. Err means no pump is selected or more than one pump is
selected.**
TEST SPEED: The speed the console uses for stationary tests of the sprayer.**
SCAN: Err: This is an invalid switch combination.
NOTES:
* Totals can be zeroed in this mode.
** Values are programmable in this mode.
*** Values changeable by a % increase or decrease.