1.4.2 DISPLAY SELECTOR FUNCTIONS IN SET UP MODE

(Refer to Appendix D for these switch functions in "Handgun Mode".)

MID-TECH

MIDWEST TECHNOLOGIES, INC.

CHEMICAL APPLICATORS

1

2

3

ON

OFF

Alt.-

Rate

TASC-6600

TOTAL APPLICATION

SPRAYER CONTROL

1

2

3

4

5

6

7

8

9

BOOMS

4

5

6

.

-Ac

Flow

RATE

Gal./

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

%Rate

DISPLAY SELECTOR

Speed

Area

Width

Distance

Chem. Applied

Test

Speed

Prime

Total Applied

Chem. Rate

Appl. Rate

CHEMICALS

CARRIER

Scan

MID-TECH

MIDWEST TECHNOLOGIES, INC.

ON

OFF

Alt.-

Rate

TASC-6600

TOTAL APPLICATION

SPRAYER CONTROL

1

2

3

4

5

6

7

8

9

BOOMS

6

Ac

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

%Rate

DISPLAY SELECTOR

Speed

Area

Width

Distance

Chem. Applied

Test

Speed

Prime

Total Applied

Chem. Rate

Appl. Rate

CHEMICALS

CARRIER

Scan

%Rate

DISPLAY SELECTOR

Speed

Area

Width

Distance

Chem. Applied

Test

Speed

Prime

Total Applied

Chem. Rate

Appl. Rate

CHEMICALS

CARRIER

Scan

MID-TECH

MIDWEST TECHNOLOGIES, INC.

Ac

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

MID-TECH

MIDWEST TECHNOLOGIES, INC.

-Ac

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

OFF

SET- UP

DEC.

ON

OPERATE

INC.

SPEED: Ground Speed Override (GSO) Value

AREA: Accumulated Area #2.*

CHEMICALS CHEM. APPLIED: Injection pump calibration number for the pump that is turned ON. Err means no

pump is selected or more than one pump is selected.**

CHEMICALS CHEM. RATE: The volume per acre to be delivered by an individual injection pump. Each pump must

be selected ON in sequence. Two rates are programmable, one in each position of the injection pump switch: ON -
Standard Rate or Alt. Rate - Alternate Rate. Err means no pump is selected or more than one pump is selected.**

CHEMICALS % RATE: The percent of change applied to all active injection pump application rates for each actuation

of the INC/DEC switch.**

CARRIER APPL. RATE: The target application rate of the main carrier, including injected chemical.**

CARRIER TOTAL APPLIED: The flow meter calibration number**

WIDTH: Individual boom section widths. The display cycles through the individual boom sections sequentially, unless

a particular boom switch is activated.**

DISTANCE: The current distance calibration number.**

PRIME: The prime volumes for the pump that is turned ON. Err means no pump is selected or more than one pump is

selected.**

TEST SPEED: The speed the console uses for stationary tests of the sprayer.**

SCAN: Err: This is an invalid switch combination.

NOTES:

* Totals can be zeroed in this mode.
** Values are programmable in this mode.
*** Values changeable by a % increase or decrease.