1.4.1 DISPLAY SELECTOR FUNCTIONS IN OPERATE MODE
(Refer to Appendix D for these switch functions in "Handgun Mode".)
MID-TECH
MIDWEST TECHNOLOGIES, INC.
CHEMICAL APPLICATORS
1
2
3
ON
OFF
Alt.-
Rate
TASC-6600
TOTAL APPLICATION
SPRAYER CONTROL
1
2
3
4
5
6
7
8
9
BOOMS
4
5
6
.
-Ac
Flow
RATE
Gal./
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Chem. Applied
Test
Speed
Prime
Total Applied
Chem. Rate
Appl. Rate
CHEMICALS
CARRIER
Scan
MID-TECH
MIDWEST TECHNOLOGIES, INC.
ON
OFF
Alt.-
Rate
TASC-6600
TOTAL APPLICATION
SPRAYER CONTROL
1
2
3
4
5
6
7
8
9
BOOMS
6
Ac
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Chem. Applied
Test
Speed
Prime
Total Applied
Chem. Rate
Appl. Rate
CHEMICALS
CARRIER
Scan
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Chem. Applied
Test
Speed
Prime
Total Applied
Chem. Rate
Appl. Rate
CHEMICALS
CARRIER
Scan
MID-TECH
MIDWEST TECHNOLOGIES, INC.
Ac
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
MID-TECH
MIDWEST TECHNOLOGIES, INC.
-Ac
®
OFF
SET- UP
DEC.
ON
OPERATE
INC.
OFF
SET- UP
DEC.
ON
OPERATE
INC.
SPEED: The current vehicle speed.
AREA: Accumulated Area #1.*
CHEMICALS CHEM. APPLIED: The amount of chemical actually pumped by each injection pump. The display
cycles through each pump in sequence unless a specific pump switch is selected ON.*
CHEMICALS CHEM. RATE: The programmed application rate to be delivered by each injection pump. The display
cycles through each pump in sequence unless a specific pump switch is selected ON. An alternate rate can also be
programmed for each pump. In order to view the Alternate rate, the individual pump switch must be set to the ALT.
RATE position.
CHEMICALS % RATE: The percent of target application rate at which all active injection pumps are operating. This
percentage can be changed up or down a preset amount by operating the INC/DEC switch.***
CARRIER APPL. RATE: The target application rate of the main carrier (including chemical). Once spraying opera-
tions have started, and main carrier flow is established, the actual measured flow rate of the sprayer will be displayed
here.***
CARRIER TOTAL APPLIED: The actual volume of carrier, including chemical applied, as measured by the flow
meter.*
WIDTH: The active boom width. Depends on the actual boom sections selected ON and the individual widths pro-
gramed into each section.
DISTANCE: The accumulated distance.*
PRIME: This position is used during priming operations to fill the injector pump lines with chemical or to lock the
control valve open during main pump priming.
TEST SPEED: The speed the console uses for stationary tests of the sprayer.**
SCAN: The display scans SPEED, AREA, CHEMICALS-CHEM. APPLIED by active pumps, CHEMICALS-
CHEM. RATE of active pumps, CARRIER-APPL. RATE and CARRIER-VOLUME APPLIED. The display
holds at each position for approximately two seconds.
NOTES:
* Totals can be zeroed in this mode.