beautypg.com

TeeJet TASC-6600 User Manual

Page 8

background image

1-2

TASC-6000, 6300, 6600

98-05010

Rev. - 1

1.4.1 DISPLAY SELECTOR FUNCTIONS IN OPERATE MODE

(Refer to Appendix D for these switch functions in "Handgun Mode".)

MID-TECH

MIDWEST TECHNOLOGIES, INC.

CHEMICAL APPLICATORS

1

2

3

ON

OFF

Alt.-

Rate

TASC-6600

TOTAL APPLICATION

SPRAYER CONTROL

1

2

3

4

5

6

7

8

9

BOOMS

4

5

6

.

-Ac

Flow

RATE

Gal./

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

%Rate

DISPLAY SELECTOR

Speed

Area

Width

Distance

Chem. Applied

Test

Speed

Prime

Total Applied

Chem. Rate

Appl. Rate

CHEMICALS

CARRIER

Scan

MID-TECH

MIDWEST TECHNOLOGIES, INC.

ON

OFF

Alt.-

Rate

TASC-6600

TOTAL APPLICATION

SPRAYER CONTROL

1

2

3

4

5

6

7

8

9

BOOMS

6

Ac

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

%Rate

DISPLAY SELECTOR

Speed

Area

Width

Distance

Chem. Applied

Test

Speed

Prime

Total Applied

Chem. Rate

Appl. Rate

CHEMICALS

CARRIER

Scan

%Rate

DISPLAY SELECTOR

Speed

Area

Width

Distance

Chem. Applied

Test

Speed

Prime

Total Applied

Chem. Rate

Appl. Rate

CHEMICALS

CARRIER

Scan

MID-TECH

MIDWEST TECHNOLOGIES, INC.

Ac

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

MID-TECH

MIDWEST TECHNOLOGIES, INC.

-Ac

®

OFF

SET- UP

DEC.

ON

OPERATE

INC.

OFF

SET- UP

DEC.

ON

OPERATE

INC.

SPEED: The current vehicle speed.

AREA: Accumulated Area #1.*

CHEMICALS CHEM. APPLIED: The amount of chemical actually pumped by each injection pump. The display

cycles through each pump in sequence unless a specific pump switch is selected ON.*

CHEMICALS CHEM. RATE: The programmed application rate to be delivered by each injection pump. The display

cycles through each pump in sequence unless a specific pump switch is selected ON. An alternate rate can also be
programmed for each pump. In order to view the Alternate rate, the individual pump switch must be set to the ALT.
RATE
position.

CHEMICALS % RATE: The percent of target application rate at which all active injection pumps are operating. This

percentage can be changed up or down a preset amount by operating the INC/DEC switch.***

CARRIER APPL. RATE: The target application rate of the main carrier (including chemical). Once spraying opera-

tions have started, and main carrier flow is established, the actual measured flow rate of the sprayer will be displayed
here.***

CARRIER TOTAL APPLIED: The actual volume of carrier, including chemical applied, as measured by the flow

meter.*

WIDTH: The active boom width. Depends on the actual boom sections selected ON and the individual widths pro-

gramed into each section.

DISTANCE: The accumulated distance.*

PRIME: This position is used during priming operations to fill the injector pump lines with chemical or to lock the

control valve open during main pump priming.

TEST SPEED: The speed the console uses for stationary tests of the sprayer.**

SCAN: The display scans SPEED, AREA, CHEMICALS-CHEM. APPLIED by active pumps, CHEMICALS-

CHEM. RATE of active pumps, CARRIER-APPL. RATE and CARRIER-VOLUME APPLIED. The display
holds at each position for approximately two seconds.

NOTES:

* Totals can be zeroed in this mode.
** Values are programmable in this mode.
*** Values changeable by a % increase or decrease.

This manual is related to the following products: