TeeJet TASC-6600 User Manual
Page 75

D-7
TASC-6000, 6300, 6600
98-05010
Rev. - 1
Monitoring a pressure gauge, use the INC/DEC switch to set the desired pressure. You are now set to operate at a
predetermined pressure. Injection pumps will track boom width changes and speed changes to keep chemical rate per
acre constant. The console will display flow as GAL/ACRE (LITERS/HECTARE) at speeds above 1 mph. Below 1 mph
the console will display flow as GAL/MIN (LITERS/MIN).
D.3.2. NORMAL MODE, SPECIAL PURPOSE BOOM WIDTHS
For broadcast spraying operations on slopes, separate widths can be programmed into the 'B' or 'C' widths on the TASC
console. Select the "Normal" mode and 'B' Width or 'C' Width on the Boom Switch Panel. Select the Width display
function and the "SET-UP" mode on the TASC console. Enter the desired width in inches.
Now, whenever boom width 'B' or 'C' is selected on the switch panel, the TASC console will automatically adjust its
flow rate for the programmed width, regardless of the position of the individual boom valves