Roadside wiring with mid-tech switchbox, D5 - roadside system diagram w/mid-tech switchbox, Tasc-6300 console – TeeJet TASC-6600 User Manual
Page 77: Flow meter
D-9
TASC-6000, 6300, 6600
98-05010
Rev. - 1
+
Vehicle Battery
(12 Volts)
TASC-6300 CONSOLE
Pump Control
Cables
Ground Speed Sensor
120-0000-KIT
Chemical Injection Pumps
Pump Power
Cables
(120-xxxx)
Printer Module
(Optional)
Flowmeter Interface Cable
(405-0044)
Flow Control Valve
879-xxxx
Flow Control Cable
(404-0022)
Fuse,(10 amp)
Power Cable
(401-0010)
Fuse,(5 amp)
Red
Black
Battery Cable
(45-05037)
Fuse,(15 amp)
Neg.
Pos.
Connect
Direct to
BATTERY
Data Link
(Optional)
405-0069-96V
Battery Cable
(401-0011)
Valve Driver Cable
(405-0143)
TASC-6600 CONSOLE
or
Roadside Wiring
with
Mid-Tech Switchbox
CHEMICAL APPLICATORS
1
2
3
ON
OFF
Alt.-
Rate
TASC-6300
TOTAL APPLICATION
SPRAYER CONTROL
%Rate
DISPLAY SELECTOR
Speed
Area
Width
Distance
Chem. Applied
Test
Speed
Prime
Total Applied
Chem. Rate
Appl. Rate
CHEMICALS
CARRIER
OFF
SET- UP
DEC.
ON
OPERATE
INC.
1
2
3
4
5
6
7
8 9
BOOMS
Scan
MID-TECH
MIDWEST TECHNOLOGIES, INC.
.
-Ac
Flow
RATE
Gal./
®
Flow Meter
Flowsensor
120-0004 or
120-0005
1
9
B
O
O
M
S
Frame
Ground
(404-0037)
9 Boom Sense
Cable
Caution
Connect To
+12v Only
Battery
(404-0009)
Extension Cable
MIDWEST TECHNOLOGIES INC.
2733 East Ash Street
Springfield IL - (217) 753-8424
www.mid-tech.com
SPRAY MODE
NORMAL - HANDGUN
(405-0088)
Boom Control
Switchbox
BOOMS
MASTER
OFF - ON
OFF
GROUND SPEED
OVERRIDE
WIDTH
AUTO
MIDWEST TECHNOLOGIES, INC.
SPRAY MODE
NORMAL - HANDGUN
ON
"B"
"C"