2.4.2.1. S1~S4: Digital In Select

It is possible to select the Distal Input mode with this switch (S1 ~ S4). In order to use VCC Common Mode, switch
down, and to use GNC Common Mode switch up refer to below feature.
This below schematic is just for reference, So you should make you own schematic with the current and voltage
that you want.

Common Input Setting (Switch S1~S4)

MODE

Switch

설명

GND

Common

UP

Com m on GND

COM
(GND)

Isolated Input
Signal(Source)

Eddy DK v2.1

1.1K

4.7K

VCC

Common

Down

Com m on VCC

EXTERNAL POWER

Isolated Input
Signal(SINK)